Fabrication of a AGC Bar and Overdenture

1st Office AppointmentGalvano

  • Take preliminary maxillary and mandibular impressions for fabricaiton of custom tray

Laboratory Step #1

Please allow 2 working days for the following laboratory procedures 
  • Pour maxillary and mandibular preliminary castGalvano_side
  • Fabricate custom tray
  • Fabricate baseplate and occlusal rim

2nd Office Appointment

  • Take facebow (please provide articluator if other than Denar or Stratos)
  • Make centric bite record using occlusal rim
  • Take impression with pick-up impression copings utilizing GC resin to join impression copings togther

Laboratory Step #2

   Please allow 5 working days for the following laboratory procedures
  • Pour master model utilizing lab analogs in die stoneGalvano_top
  • Mount cast on adjustable articulator (Denar or Stratos)
  • Set up full denture
  • Make verification jig using GC resin screwed down to the master cast

3rd Office Appointment

  • Screw down verification jig in the mouth and verify fit with an x-ray to confirm the accuracy of the impression and teh master cast; if there is any discrepancy, section and lute together with GC resin; the lab will reset analogs on the master cast to this new relationship using the same jig
  • Wax try in of full denture

Laboratory Step #3

   Please allow 10 working days for the following laboratory procedures
  • Fabrication of gold barGalvano_beside
  • Fabrication of AGC sleeve
  • Fabrication of Suprastructure (metal frame)
  • Duplicate master model with bar
  • Silicoat sleeve and transfer set up
  • Process AGC Denture

4th Office Appointment

  • Delivery of final AGC denture with bar
 

Add comment


English (United Kingdom)